5A/10A/15A/20A/30A Solar Regulator Panel Battery Charge Controller12V/24V Auto Autoswitch 5A/10A/15A/20A/30A Solar Regulator Panel Battery Charge Controller12V/24V Auto Autoswitch 5A/10A/15A/20A/30A Solar Regulator Panel Battery Charge Controller12V/24V Auto Autoswitch
Next

5A/10A/15A/20A/30A Solar Regulator Panel Battery Charge Controller12V/24V Auto Autoswitch

FOB Price

Get Latest Price

8 ~ 11 / ( Negotiable )

|

50 Piece Minimum Order

Country:

China

Model No:

-

FOB Price:

8 ~ 11 / ( Negotiable ) Get Latest Price

Place of Origin:

-

Price for Minimum Order:

8

Minimum Order Quantity:

50 Piece

Packaging Detail:

box

Delivery Time:

10 to 20days

Supplying Ability:

500 Piece per Day

Payment Type:

PayPal

Product Group :

Contact Now

ayb

China

Free Member

Contact Person A

Xin'an 6th Rd, Xi'xiang Bao'an District, Shenzhen, Guangdong

Contact Now

Product Specification

  • Application: Charger Controller
  • Rated Voltage: 12V

Product Description

MPPT SOLAR CHARGE CONTROLLER

 

1. SAFETY

Full consideration to the safety of persons and property has been given when designing the products. However the incorrect connection may cause the system breakdown or even safety accident. For your safety and benefits, the following rules must be complied during the operation.

. Installation of this product shall be tinder the guidance of the professionals in this field.

. Prevent this controller from water, humidity and insects, to avoid short-circuit.

. Keep children and incapable persons away from the controller

. Keep the controller away from electrical heater, heating machine and other high temperature electrical appliances; avoid the controller suffering from insulation directly.

. Please check the rated voltage of solar panel, battery, and loads before connection. *2V rated voltage is *2V, *4V rated voltage is *4V, *8V rated voltage is *8V.

. Make sure connections between positive and negative poles of Solar panels, Battery and Loads are correct.

. The diameter of connecting cable must be matched with the requirements of the current. Do not use thinner diameter cable, the thinner diameter. The larger resistance, this will cause higher temperature and output power decreasing.

. The total rated current of solar panel and loads must be smaller than the rated current of the controller.

. Components of system must be correctly and firmly connected. Prevent the terminals from oxidation and moldy, to avoid connection trouble.


 

2. FEATURES

. MPPT solar charge controller MPPT****0: Compared with normal solar charge controller, this MPPT controller could increase efficiency by *0%**0%.

. This controller can charge and discharge at the same time.

. This MPPT controller has perfect SOC function, control charge current, and supply power to the loads.

Function:

. Always keep the battery on fill voltage condition.

. Prevent the battery from over-charging.

. Prevent the battery from over-discharging.

. Prevent the battery from reverse charging to solar panels during nights.

. Reverse Polarity Protection for Battery

. Reverse Polarity Protection for Solar Panels

. When the battery voltage is low, the controller will automatically cut off the load from the system. If the voltage of battery is back to normal and the load will restart working.

. Thunder protection

. According to the battery voltage grade, the controller can automatically set charge-off voltage, the load-off voltage, the load- restore voltage. (The parameter is default under *5
condition, locked by the CPU procedure, cannot adjust.)


. The controller will automatically compensate the temperature of the charging voltage according to the changes of ambient temperature.

  

 

Warning:

Before connecting to the solar panel, please connect the controller to the battery; do not use solar panel supply power to the loads directly.

Notes:

Do not use lamplight to charge the solar panel (lamplight is too weak to charge)

DC power source to replace the solar panel will cause troubles to controller.


Choose the suitable wire which diameter should not be too small, please refer to the parameter.

 

4. INDICATE LIGHT AND BUTTON

. When Red LED (CHARGE) is on, battery is charged up strongly; When Red LED is flickering, battery is MPPT charged up in constant voltage; when Red LED is oft charge off

. When Green LED (LOAD) is on, loads are working; when Green LED (LOAD) is off, loads stop working.

. Three Color-changing LED (BATTERY), When light is red, it indicates low voltage, green indicate battery full charged, orange indicate normal status.


Color-changing LED working voltage indicates area: 























 

Color-changing LED *2V *4V
Red LED *0.5V**1V *1V**2V
Orange LED *0.5*1V**3.7V

 
*1*2V**7.4V

 
Green LED ≥*3.7V ≥ *7.4V

5. PARAMETERS























































































 
Rated Vo1tae *2V / *4V
MaxLoad current *0A *5A *0A *0A *0A 5OA *0A
Input voltage range *2V*0V/*4
Length≤1m

Charge loop drop
<**0mV <**0mV <**0mV <**0mV <**0mV <**0mV <**0mV
Length≤1m

Discharge loop drop
<*0mV <*0mV <*0mV <*0mV <*0mV <*0mV <*0mV
Full charge cut 1.*7V*4.4V/*7.4V*8.8V/*4.8V*7.6V (data under no load condition)
Low voltage cut *0.5VllV / *1V*4V
Temperature compensation *3mV//cell
No load loss ≤*0mV ≤*0mV ≤*0mV ≤*0mV ≤*0mV ≤*0mV ≤*5mV
Efficiency *5%*7% *5%*7% *5%*7% *5%*7% *5%*7% *5%*7% *5%*7%
Max wire area 2.5mm2 2.5mm2 4mm2 6mm2 8mm2 *0mm2 *2mm2
Ambient temperature **5—*5

6. TROUBLE SOLUTION

Phenomenon:Green LED off, battery indicator LED is red.

Reason: Low voltage of battery

Solution:

A:Cut off the power, disconnect the load; reconnect the load after the charge become normal.

B:Batterycharge problem: Increase the solar panel power or change the battery.

Phenomenon:Batteryindicator LED is orange and Load indicator LED is green, the loads cannot work.

Reason:Over load or short-circuit causes the controller inner fuse cut off


Solution:*0**0 minutes after eliminated the malfunction, the fuse will automatically back to working. 

 

Country: China
Model No: -
FOB Price: 8 ~ 11 / ( Negotiable ) Get Latest Price
Place of Origin: -
Price for Minimum Order: 8
Minimum Order Quantity: 50 Piece
Packaging Detail: box
Delivery Time: 10 to 20days
Supplying Ability: 500 Piece per Day
Payment Type: PayPal
Product Group : solor controller

Related Products ayb

Send a direct inquiry to this supplier

To:

A < ayb >

I want to know: